图片 | 型号 | 库存 | 数量 | 规格书 | 系列 | 包装 | 产品状态 | 框架类型 | 装载侧 | 腔高度 | 腔宽度 | 最小弯曲半径 | 外部高度 | 外部宽度 | 长度 | 链条节距 | 特性 | 材质 | 工作温度 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
E2I-15-13-028-0CABLE CARRIER .76H X .82W 1=1FT |
192 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.510" (12.95mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 0.820" (20.83mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2-15-13-028-0CABLE CARRIER .76H X .82W 1=1FT |
177 |
|
![]() 规格书 |
E2-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.510" (12.95mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 0.820" (20.83mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-15-16-028-0CABLE CARRIER .76H X .92W 1=1FT |
4,983 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.630" (16.00mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 0.920" (23.37mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-15-16-048-0CABLE CARRIER .76H X .92W 1=1FT |
200 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.630" (16.00mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 0.920" (23.37mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-15-16-038-0CABLE CARRIER .76H X .92W 1=1FT |
164 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.630" (16.00mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 0.920" (23.37mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
Z14-1-028-0CABLE CARRIER .98H X 1.06W 1=1FT |
250 |
|
![]() 规格书 |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-1-048-0CABLE CARRIER .98H X 1.06W 1=1FT |
190 |
|
![]() 规格书 |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.890" (48.01mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-1-038-0CABLE CARRIER .98H X 1.06W 1=1FT |
190 |
|
![]() 规格书 |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.500" (38.10mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-1-028-0CABLE CARRIER .98H X 1.06W 1=1FT |
180 |
|
![]() 规格书 |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-1-038-0CABLE CARRIER .98H X 1.06W 1=1FT |
179 |
|
![]() 规格书 |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.500" (38.10mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-1-048-0CABLE CARRIER .98H X 1.06W 1=1FT |
176 |
|
![]() 规格书 |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.590" (14.99mm) | 1.890" (48.01mm) | 0.980" (24.89mm) | 1.060" (26.92mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E2I-15-20-038-0CABLE CARRIER .76H X 1.08W 1=1FT |
200 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.790" (20.07mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 1.080" (27.43mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2-15-20-048-0CABLE CARRIER .76H X 1.08W 1=1FT |
196 |
|
![]() 规格书 |
E2-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.790" (20.07mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 1.080" (27.43mm) | 12.000" (304.80mm) | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-15-20-048-0CABLE CARRIER .76H X 1.08W 1=1FT |
195 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.790" (20.07mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 1.080" (27.43mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-15-20-028-0CABLE CARRIER .76H X 1.08W 1=1FT |
180 |
|
![]() 规格书 |
E2I-15 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 0.790" (20.07mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 1.080" (27.43mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
14-2-028-0CABLE CARRIER .98H X 1.42W 1=1FT |
266 |
|
![]() 规格书 |
14 | Bulk | Active | Open | Inside and Outside Bend | 0.790" (20.07mm) | 0.980" (24.89mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.420" (36.07mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E08-40-048-0CABLE CARRIER .76H X 1.90W 1=1FT |
200 |
|
![]() 规格书 |
E08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.570" (39.88mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 1.900" (48.26mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-40-048-0CABLE CARRIER .76H X 1.90W 1=1FT |
200 |
|
![]() 规格书 |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.570" (39.88mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 1.900" (48.26mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-40-038-0CABLE CARRIER .76H X 1.90W 1=1FT |
200 |
|
![]() 规格书 |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.570" (39.88mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 1.900" (48.26mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-40-028-0CABLE CARRIER .76H X 1.90W 1=1FT |
194 |
|
![]() 规格书 |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.570" (39.88mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 1.900" (48.26mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |