图片 | 型号 | 库存 | 数量 | 规格书 | 系列 | 包装 | 产品状态 | 功能 | 电压 - 电源 | 触发范围 | 延迟时间 | 安装类型 | 端接样式 | 特性 | 工作温度 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
G2JM5AL20 24-240V AC/DC3-PH CURRENT RELAY, 5A |
2,129 |
|
![]() 规格书 |
- | Box | Active | Ground Fault , Overcurrent, Undercurrent | 24 ~ 240VAC/DC | 5 ~ 6A | 0.1 ~ 10s | DIN Rail | Screw Terminal | Automatic Reset | -25°C ~ 40°C |
![]() |
APVR-120PHASE LOSS & PHASE SEQUENCE |
3,824 |
|
![]() 规格书 |
* | Retail Package | Active | - | - | - | - | - | - | - | - |
![]() |
ZVM-600PMV RELAY 120VAC ADJ 40-400MV DPD |
4,330 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 115VAC | - | - | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-120A-S1C-00002MV RELAY 120VAC, ADJ 35-430MV, |
1,608 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | - | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-120A-S1C-00002MV RELAY 120VAC ADJ 35-430MV SPD |
2,051 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | - | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-120A-A2AMV RELAY 120VAC ADJ 35-430MV 2NO |
4,431 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-240A-A1CMV RELAY 240VAC ADJ 35-430MV SPD |
3,004 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 208 ~ 240VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-24A-A1CMV RELAY 24VAC, ADJ 35-430MV SPD |
4,728 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 24VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-120A-AABMV RELAY 120VAC, ADJ 35-430MV 1N |
1,628 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-240A-A2AMV RELAY 240VAC ADJ 35-430MV 2NO |
4,958 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 208 ~ 240VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-120A-FABMV RELAY 120VAC FIX 35MV 1NO 1NC |
2,905 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 1s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-120A-F2AMV RELAY 120VAC, FIX 35MV 2NO |
2,653 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 1s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-120A-FABMV RELAY 120VAC, FIX 35MV 1NO 1N |
3,552 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 1s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-120A-F2AMV RELAY 120VAC FIX35MV 2NO |
4,798 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 1s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-240A-A1CMV RELAY 240VAC, ADJ 35-430MV SP |
4,336 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 208 ~ 240VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-240A-F1CMV RELAY 240VAC, FIX 35MV SPDT |
2,288 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 208 ~ 240VAC | 38 ~ 380VAC | 1s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVR-120A-AABMV RELAY 120VAC ADJ 35-430MV 1NO |
1,429 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 0.5 ~ 40s | Chassis Mount, DIN Rail | Screw Terminal | - | 0°C ~ 65°C |
![]() |
ZVS-120A-F1CMV RELAY 120VAC, FIX 35MV SPDT |
2,930 |
|
![]() 规格书 |
- | Box | Active | Overvoltage | 100 ~ 120VAC | 38 ~ 380VAC | 1s | Chassis Mount | Screw Terminal | - | 0°C ~ 65°C |
![]() |
1SVR730660R0100Insulation Monitoring Relay, |
1,830 |
|
![]() 规格书 |
* | Retail Package | Active | - | - | - | - | - | - | - | - |
![]() |
G4BM480V12ADTL20 24-240V AC/DCPOWER MONITOR PUMP SAVER |
2,308 |
|
![]() 规格书 |
- | Box | Active | Ground Fault , Overload, Overtemperature, Underload | 24 ~ 240VAC/DC | 48 ~ 480VAC | 0.1 ~ 50s | DIN Rail | Screw Terminal | Automatic Reset | -25°C ~ 40°C |